
70-223 Configuring and Administering Microsoft Clustering Services by using Microsoft Windows 2000 Advanced
Exam24.jpはお客様が70-223質疑応答を使用すれば試験に合格することを100パーセント保証できます。もしお客様は、試験に失敗したら、どうしますか?お客様は、我々を知らせて、支払いの方式で試験資料の料金を全額返金いたします。よろしければ、われわれはお客さんの購読時間を延ばして、より多くの訓練時間があってもう一度試して見てきます。お客さんに決められるよ!
以下は問題集のPDF版の一部の内容です。
1. You are the cluster administrator for your company. You need to configure two Windows 2000Advanced Server computers for use as cluster nodes. You need to implement fault-tolerance methods forthe local storage. You also need to implement fault-tolerance methods for the external storagesubsystem.Each server contains two 9.3-GB hard disks. The external storage subsystem contains eight 10-GB hard
disks. You need to ensure that the cluster can tolerate the failure of a single hard disk in either server andin the external storage subsystem.
Which two fault-tolerance methods should you use? (Choose two.)
A. Configure the hard disks in each server as Windows 2000 striped volumes.
B. Configure the hard disks in each server as Windows 2000 RAID 5 volumes.
C. Configure the hard disks in each server as Windows 2000 mirrored volumes.
D. Configure the hard disks in the external storage subsystem to use a hardware RAID 5 array.
E. Configure the hard disks in the external storage subsystem as Windows 2000 striped volumes.
F. Configure the hard disks in the external storage subsystem as Windows 2000 RAID 5 volumes.
Answer: CD
2. You are the administrator of two new computers. You need to configure the computers before installingWindows 2000 Advanced Server and the Cluster service. You install a new SCSI controller in eachcomputer. You connect both controllers to an external disk array, which will serve as the cluster storage.The external disk array contains three hard disks. You start both servers and receive a BIOS errormessage on each server. The error message indicates that a device conflict has been detected on theSCSI bus. You need to correct this error.
What should you do?
A. Change the SCSI ID to 0 on all three hard disks.
B. Change the SCSI ID on one of the SCSI controllers.
C. Add a SCSI bus terminator to the connector on the external disk array.
D. Add a SCSI bus terminator to the connectors on both SCSI controllers.
Answer: B
3. You are the administrator of a Windows 2000 Advanced Server computer. You need to prepare theserver for use as a cluster node. The server contains a SCSI controller and three internal 4.3-GB harddisks. You plan to attach the server to an external storage subsystem that contains eight 18.3-GB harddisks. You connect the three 4.3-GB hard disks to the SCSI controller’s internal connector. Next, youconnect the external storage subsystem to the SCSI controller’s external connector. When you start the
server, you receive numerous BIOS error messages that indicate errors on the SCSI bus. Before installingthe Cluster service, you need to be able to access the internal and external disks that are attached to theserver.
What should you do?
A. Replace the SCSI controller.
B. Replace the external SCSI cable.
C. Set the SCSI ID to 6.
D. Install an additional SCSI controller in the server.
Connect the external drive array to the new controller’s external connector.
E. Disable the on-board SCSI termination on the SCSI controller.
Connect a SCSI terminator to the SCSI-out connector on the external storage subsystem
Answer: D
お客様は、何か問題あるなら、何時でもご連絡してください。私達はお客さんの70-223認証に関連する問題の処理を助けます。私達は、お客さんを満足させてこそ、わが社が発展することが出来ますと信じています。